Page tree
Skip to end of metadata
Go to start of metadata

Description

You receive the validation error before executing BI Template.

Error

"Validation Error: Test SLD connection:It was not possible to test the SLD system (SLD_HOST) with the user (SLD_ADMIN) and its password given in the property sheet. Please verify and retype the values in the corresponding fields. You can also go to visual administrator -> "SID" -> Server xx -> Services -> Configuration adaptor -> CTC -> Propertysheet SystemProperties, make sure that the parameters related to   SLD are correctly typed and rerun the template."

Solution

There are 2 cases in which you receive this validation error:

Case 1:  When you use HTTPs connection to the SLD

Solution 1: Apply Patch 3, SP 15 - a new option for BI configuration that switches off sld check. If you switch off sld check you have to create the JCo destinations manually*. Refer to the note# 923359 to know more about applying patchches.

Case 2: When you run Template Installer after upgrade or additional usage type enablement (JSPM).

Solution 2: SLD parameters in Visual Admin are missing. These are not supported scenarios and only manual configuration is possible.