Symptom

"Could not verify if the backend of system <NAME_OF_THE_SYSTEM> is configured for optimized delta pull" message is displayed upon attempt to configure Delta Pull for the WebFlowConnector

Problem

  • Problem A: This topic relates to the problem where registering a newly created connector of type WebFlowConnector in System Administration -> Universal Worklist Administration yields a warning message "Could not verify if the backend of system <NAME_OF_THE_SYSTEM> is configured for optimized delta pull" although background jobs UWL_FULL and DELTA exist and are scheduled on the ABAP system.
    In additionthe execution of function module UWL_DETECT_BWF_DELTA_JOB returns that Delta Pull is not enabled.
  • Problem B: Another reason for this behavior might be that RFC destination for Universal Worklist is configured with option "Load Balancing: No". in that case, a workaround solution would be to manually set "Load Balancing:" option to "Yes".

Keywords

  • Delta Pull UWL
  • UWL_DETECT_BWF_DELTA_JOB
  • UWL_FULL
  • DELTA

Solution

  • Problem A: This behavior has been fixed. Refer to SAP Note 1373161. Check for valid releases that contain the fix or, for lower releases, apply corrective instructions documented in SAP Note 1373161