Workflow
1) In the CCM, change the default location of the FRS to a share.
2) In the CMC, update the Input and Output FRS servers on the BI platform servers to the shared location.
To change the FRS location in the CCM
By default, the FRS is located here C:\Program Files (x86)\SAP BusinessObjects\SAP BusinessObjects Enterprise XI 4.0\FileStore
. It needs to be moved to share on the WINFRS01 machine.
1) Log in to the machine Vantgvmpb04
using an administrator account.
2) To open the CCM, click Start > All Programs > SAP BusinessObjects BI Platform 4 > SAP BusinessObjects BI platform > Central Configuration Manager(CCM).
3) Right-click Server Intelligence Agent, and click Stop.
4) When the SIA has stopped, to access the FRS share, click Start > Run, and in the "Run" dialog box, type the path to the FRS share: \WINFRS01\FRS
.
5) Copy the Input
folder and Output
folder from C:\Program Files (x86)\SAP BusinessObjects\SAP BusinessObjects Enterprise XI 4.0\FileStore
to \\WINFRS01\FRS
6) Once the files are copied, count the folders and files in both locations to ensure they match in number.
To update the Input and Output FRS servers on BIP servers to the shared location
Follow these steps to update the Input and Output FRS servers on the BI platform servers to the shared location.
1) To start the SIA service, in the CCM, right-click Server Intelligence Agent, and click Start.
2) Log in to the Central Management Console (CMC) as an Administrator.
3) Click Servers.
4) Click Core services.
5) Hold down the CRTL key, and click on the following Input and Output servers:
- VANTGVMWINPB04.InputFileRepository
- VANTGVMWINPB05.InputFileRepository
- VANTGVMWINPB04.OutputFileRepository
- VANTGVMWINPB05.OutputFileRepository.
6) Right-click any of the selected servers, and click Disable Server.
7) Double-click VANTGVMWINPB04.InputFileRepository
.
8) In the "Input Filestore Service" area, in the File Store Directory box type the following text:
\\WINFRS01\FRS\Input
9) In the Temporary Directory box, type \\WINFRS01\FRS\Input\temp.
10) To save the changes, click Save & Close.
11 Repeat Steps 7 to 10 for the VANTGVMBIP05.InputFileRepository
server.
12) Repeat steps 7 to 10 for Output FRS servers VANTGVMWINPB04.OutputFileRepository
and VANTGVMWINPB05.OutputFileRepository
.
Ensure that the following path is used: \\WINFRS01\FRS\Output
13) Restart each of the modified servers to commit the changes: hold down the CRTL key, and click on the following Input and Output servers:
- VANTGVMWINPB04.InputFileRepository
- VANTGVMWINPB05.InputFileRepository
- VANTGVMWINPB04.OutputFileRepository
- VANTGVMWINPB05.OutputFileRepository.
14) Rght-click any of the selected servers, and click Enable Server.
You have successfully updated the input and output FRS servers in the CMC.